Is an adequate number of accessible parking spaces available?
No


Are the accessible aisles part of the route to the accessible entrance?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Is the route at least 0.9 m in width?
No


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes


Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
No


Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes


Are all ramps longer than 2 meters have railings on both sides?
No


Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
Yes


If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
Yes


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
No


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
No


If provided are carpeting or mats a maximum 1 cm height?
Yes


Are edges of carpeting or mats security installed to minimize tripping hazards?
No


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
No


If the door has a closer does it take at least 3 seconds to close?
Yes


General text description:
"لا يوجد مصفات مخصصة لذوي الاعاقة و لكن موجود مصف اقرب ما يكون للبوابة الرئيسية و الرصيف غير مستقيم و يتفاوت بالارتفاع ، المحدر شديدة الانحدار و غير ملائمة لذوي الاعاقة فبحاجة لمساعدة شخص اخر ، توجد مداخل و ممرات تفي بالغرض و لكن ليست مخصصة بشكل كي لذوي الاعاقة . باب العيادة الخارجي لايمكن فتحه بالقبضة المغلقة و وزنه ثقيل بعض الشيء "

Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Are all public spaces have an accessible route of travel?
No


Is the accessible route to all public spaces at least 0.9 meters wide?
Yes


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
No


Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle, so that a person using wheelchair or crutches can get near to open the door?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
Yes


Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
No


In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
No


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


Are signs mounted with Centerline 1.53 meters from the floor?
No


are the signs mounted on the wall adjacent to latch side of door or as close as possible to the door handle?
Yes


Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
No


Is the text of the sign brailed of the same information?
No


Are the spaces for wheelchair distributed throughout?
Yes


Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes


At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
Yes


On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
No


Are there ramps, lifts or elevators to all public levels?
Yes


Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
Yes


Are the call buttons in the hallway no higher than 1 meters?
No


Do controls inside the cab have raised and braille lettering?
Yes


Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No


Is the emergency intercom identified by braille and raised letters?
No


General text description:
"لا توجد طرق وممرات مخصصة لذوي الاعاقة و لكنها تؤدي الغرض و المساحة داخلية مناسبة بعض الشيء اذا تم تحريك الاثاث الموجود. الابواب يمكن فتحها باستخدام القبضة المغلقة و ارتفاع المقابض يزيد عن المعيار المحدد. داخل العيادة يوجد شاشتان بروزهما غير مهيء . اللافتات ارتفاعها غير مناسب و ليست مدعومة بلغة بريل ، أزرار المصعد أمرتفعة بعض الشيء من الداخل و الخارج "

If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
No


General text description:
يوجد وحدة صحية للعامة و لكنه غير مهيئ لذوي الاعاقة الحركية و البصرية

General text description:
لا يوجد

Customer Reviews

5

(0 Rating)

Customers Comments

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able

Subscribe to our newsletter and don’t miss any updates