Is an adequate number of accessible parking spaces available?
Yes


Is the car parking 2.5 meters in width plus 1.5-meters access aisle?
Yes


Is there a 2.5 meters wide space with minimum 2.5 meters wide access aisles and 2.5 meters of vertical clearance available for lift equipped vans?
Yes


Are the accessible aisles part of the route to the accessible entrance?
Yes


Are the accessible parking spaces close to the accessible entrance?
Yes


Is the accessible parking space marked (or painted on street) with the International symbol of accessibility? are these signs reading "van-accessible" at van signs?
No


Is there an enforcement procedure to ensure that accessible parking is used only by those who need it?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Is the route at least 0.9 m in width?
Yes


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes


Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
No


Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes


Do all inaccessible entrances have signs indicating the location of the nearest accessible entrance?
No


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


General text description:
يوجد طرق مهيأة لذوي الإعاقة, المصعد يوصل لمكان الطاولات لكن مساحته صغيرة و المدخل الثاني من داخل الكافيه مساحته مناسبة إلا إنه غير مزود بمنحدر للوصول لمنطقة الطاولات, و منطقة الترس غير مهيأة لعدم امكانية الوصول للمنطقة من ذوي الاعاقة

Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Are all public spaces have an accessible route of travel?
No


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
No


2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
Yes


Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
No


In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


If emergency systems are provided, do they have both flashing lights and audible signals?
Yes


Are signs mounted with Centerline 1.53 meters from the floor?
No


Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
No


Is the text of the sign brailed of the same information?
No


Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
No


Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes


Are knee spaces at accessible tables at least 0.68 meters high, 0.76 meters wide and 0.48 deep?
No


At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
No


Is there a portion of for ordering counters that is no more than 0.9 meters high, or is there space at the side for passing items to customers who have difficulty reaching over a high counter?
Yes


On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
No


If there is no elevator, ramp or lift, do the stairs treads have a non-slip surface?
Yes


If there is no elevator, ramp or lift, do the stairs have continued rails on both sides, with extensions beyond the top and bottom stairs?
No


Are there ramps, lifts or elevators to all public levels?
No


Are the call buttons in the hallway no higher than 1 meters?
No


Do controls inside the cab have raised and braille lettering?
Yes


Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No


Is the emergency intercom identified by braille and raised letters?
No


General text description:
يحتاج تحسين من ناحية الوصول من داحل المول و بحاجة زيادة المسافة بين الطاولات و لا يمكن الوصول للترس العلوي لذوي الإعاقة الحركية المستدعية لكرسي متحرك

Does entry configuration provide adequate maneuvering space for a person using a wheel chair?
Yes


General text description:
لا يوجد حمام مخصص أو مهيأ لذوي الاعاقة ,

General text description:
لا يوجد صراف آلي داخل المنشأة إلا أنه موجود بالمول

Customer Reviews

5

(0 Rating)

Customers Comments

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able