Orthopedic center


Overview

JUST-Able Evaluation  

Is an adequate number of accessible parking spaces available?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes


Is the route at least 0.9 m in width?
No


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes


Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes


Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
No


Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes


Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
Yes


If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
Yes


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
No


If provided are carpeting or mats a maximum 1 cm height?
Yes


Are edges of carpeting or mats security installed to minimize tripping hazards?
No


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
No


If the door has a closer does it take at least 3 seconds to close?
Yes


General text description:

Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Are all public spaces have an accessible route of travel?
Yes


Is the accessible route to all public spaces at least 0.9 meters wide?
Yes


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
No


Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
Yes


Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes


In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


If emergency systems are provided, do they have both flashing lights and audible signals?
Yes


Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes


Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
Yes


Are the spaces for wheelchair distributed throughout?
Yes


Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
No


At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
Yes


On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
Yes


Are there ramps, lifts or elevators to all public levels?
Yes


Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
Yes


Are the call buttons in the hallway no higher than 1 meters?
No


Do controls inside the cab have raised and braille lettering?
Yes


Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No


Is the emergency intercom identified by braille and raised letters?
No


General text description:

If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
No


General text description:
يوجد حمام واحد للعامة ولكنه غير مهيء لذوي الإعاقة حيث أن مساحته بعرض أقل من 1.5 متر

General text description:

Customer Reviews

5

(0 Rating)

Customers Comments

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able

Subscribe to our newsletter and don’t miss any updates