Professional Associations Complex ( Services and Meetings hall) / Irbid


Overview

JUST-Able Evaluation  

Is an adequate number of accessible parking spaces available?
No


Is there an enforcement procedure to ensure that accessible parking is used only by those who need it?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Is the route at least 0.9 m in width?
Yes


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
No


Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
Yes


Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes


Are all ramps longer than 2 meters have railings on both sides?
No


Is the width between railings or curbs at least 0.9 meters?
Yes


Are the railings sturdy and between 0.84 and 1 meters in height?
Yes


If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
Yes


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


General text description:
يوجد منحدر من الشارع للرصيف و منحدر اخر من الرصيف للمدخل و هو طويل لكنه مطابق للمواصفات ولكن لا يوجد درابزين على كلتا الجهتين و لا يوجد لافتات و المنحدر الوحيد الذي يصل بين الشارع و الرصيف ولكن تعيقه السيارات امامه

Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Are all public spaces have an accessible route of travel?
No


Is the accessible route to all public spaces at least 0.9 meters wide?
Yes


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes


Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle, so that a person using wheelchair or crutches can get near to open the door?
No


Can doors be opened without too much force, are they operable with a closed fist?
Yes


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes


In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


Are signs mounted with Centerline 1.53 meters from the floor?
No


are the signs mounted on the wall adjacent to latch side of door or as close as possible to the door handle?
Yes


Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
No


Is the text of the sign brailed of the same information?
No


If a pictogram is used is it accompanied by raised characters and braille?
No


Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes


Are they operable with a closed fist?
Yes


Are the spaces for wheelchair distributed throughout?
No


On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
Yes


Are there ramps, lifts or elevators to all public levels?
Yes


Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
No


Are the call buttons in the hallway no higher than 1 meters?
Yes


Do controls inside the cab have raised and braille lettering?
Yes


Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No


General text description:
"الخدمات غير متاحة دائما بحيث ان استخدام دورات المياه يتطلب منك ان تسأل موظف الاستقبال حتى يعطيك المفتاح ولكن المتبقي بأمكان ذوي الاحتياجات الخاصة ان يخدم نفسه و يفتح الابواب و يستعمل المصعد"

Is the doorway at least 0.9 meters clear?
Yes


Are doors equipped with accessible handles (operable with closed fist), 1-meter high?
Yes


Can doors be opened easily (operable with closed fist)?
Yes


Does entry configuration provide adequate maneuvering space for a person using a wheel chair?
Yes


General text description:
غرف الحمام غير متاحة للعامة ولكن يجب طلب استعمالها من قبل الادارة و لكن مساحتها اكثر من 1.5 م فيمكن الدخول بسهولة

General text description:
لا يوجد خدمات اضافيه

Customer Reviews

5

(0 Rating)

Customers Comments

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able

Subscribe to our newsletter and don’t miss any updates