Royal Academy for Nature Conservation/ Wild Jordan


Overview

JUST-Able Evaluation  

Is an adequate number of accessible parking spaces available?
No


Are the accessible aisles part of the route to the accessible entrance?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
No


Is the route at least 0.9 m in width?
Yes


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes


Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes


Are the slopes of ramps between the ratio of 1:10 - 1:12 meters?
Yes


Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes


Are all ramps longer than 2 meters have railings on both sides?
Yes


Is the width between railings or curbs at least 0.9 meters?
Yes


Are the railings sturdy and between 0.84 and 1 meters in height?
Yes


Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
No


If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
Yes


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
No


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


General text description:
لا يوجد موقف مخصص واشارة تدل عليه والمنحدر له عتبة اكثر من ٣ سم لكن يوجد موقف ويمكن استخدامة وقريب من المنحدر

Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Are all public spaces have an accessible route of travel?
Yes


Is the accessible route to all public spaces at least 0.9 meters wide?
Yes


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes


Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle, so that a person using wheelchair or crutches can get near to open the door?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
Yes


2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
Yes


Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
Yes


In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
Yes


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


If emergency systems are provided, do they have both flashing lights and audible signals?
Yes


Are signs mounted with Centerline 1.53 meters from the floor?
Yes


If mounted above 2 meters, do they have letters at least 0.07 meters high, with high contrast, and non-glare finish?
Yes


are the signs mounted on the wall adjacent to latch side of door or as close as possible to the door handle?
Yes


Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
Yes


Is the text of the sign brailed of the same information?
No


If a pictogram is used is it accompanied by raised characters and braille?
No


Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
Yes


Are the spaces for wheelchair distributed throughout?
Yes


Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes


Are knee spaces at accessible tables at least 0.68 meters high, 0.76 meters wide and 0.48 deep?
Yes


At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
Yes


Is there a portion of for ordering counters that is no more than 0.9 meters high, or is there space at the side for passing items to customers who have difficulty reaching over a high counter?
Yes


General text description:
المنحدر لا يحقق النسبة يحتاج لبسطات راحة لكل ٩ امتار ويحتاج لشخص مساعد و يوجد بعض العتبات البسيطة بعض السلع مرتفع لكن مرئية ويوجد شخص للخدمة

If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
No


Are there signs at inaccessible rest rooms that give directions to accessible ones?
No


Is the doorway at least 0.9 meters clear?
Yes


Are doors equipped with accessible handles (operable with closed fist), 1-meter high?
Yes


Can doors be opened easily (operable with closed fist)?
Yes


Does entry configuration provide adequate maneuvering space for a person using a wheel chair?
Yes


Is the stall door operable with a closed fist, inside and out?
No


Is there a wheel chair accessible stall that has an area of at least 1.5 by 1.5 meters, clear of the door swing? Or is there a stall that is less accessible but that provides greater access than a typical stall (either 0.69 by 1.75 meters or 1.2 by 1.75 meters)?
No


In the accessible stall are there grab bars behind and on the side wall nearest to the toilet?
No


Is the toilet seat 0.43 to 0.48 meters high?
Yes


Is the toilet seat supported with a built-in bidet or does it have a handheld bidet?
Yes


Are the soap and hand dryers within reach ranges and usable with one closed fist?
Yes


Is the mirror mounted with the bottom edges of the reflecting surface 1.02 meters high or lower?
Yes


Is there at least 0.73 meters from the floor to the bottom or the lavatory apron and 0.35 depth (excluding pipes)?
Yes


General text description:
الحمامات غير مهيئة بمساندات ولكن باقي القياسات جيدة

General text description:
لا يوجد

Customer Reviews

5

(0 Rating)

Customers Comments

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able