Is an adequate number of accessible parking spaces available?
No
Measurements
not calculated yet
View photos
No photos are attached
Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes
Measurements
not calculated yet
View photos
Is the route at least 0.9 m in width?
Yes
Measurements
العرض ١.٣٠
View photos
Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes
Measurements
not calculated yet
View photos
No photos are attached
Is the ramp stable, firm, slip resistant and blind friendly (supported textured tiling)?
No
Measurements
يوجد عتبة عند المدخل بارتفاع ١٠ سم
View photos
No photos are attached
Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes
Measurements
يوجد على بعد ٣ محلات باتجاه اليسار
View photos
Are all ramps longer than 2 meters have railings on both sides?
No
Measurements
not calculated yet
View photos
No photos are attached
Is there a 1.5 x 1.5 meters long level landing at every 9 meters’ horizontal length of the ramp, at the top and the bottom of the ramps, and at switchbacks?
No
Measurements
not calculated yet
View photos
No photos are attached
If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
No
Measurements
not calculated yet
View photos
No photos are attached
Do all inaccessible entrances have signs indicating the location of the nearest accessible entrance?
Yes
Measurements
not calculated yet
View photos
No photos are attached
Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes
Measurements
عرض الباب ٩٠ سم ولكن يوجد عائق بعرض ١٠ سم لذلك العرض المتاح ٨٠ سم
الشخص يدخل ولكن بحذر
View photos
Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
No
Measurements
not calculated yet
View photos
No photos are attached
Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
Yes
Measurements
ارتفاع العتبة ٦ سم
View photos
No photos are attached
Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes
Measurements
ارتفاع المقبض ٧٦ سم
View photos
No photos are attached
Can doors be opened without too much force, are they operable with a closed fist?
Yes
Measurements
not calculated yet
View photos
No photos are attached
If the door has a closer does it take at least 3 seconds to close?
Yes
Measurements
not calculated yet
View photos
No photos are attached
General text description:
لا يوجد اماكن اصطفاف للسيارات
لا يوجد منحدر ولكن هنالك رصيف متصل مع الشارع يمكن السير عليه
ويوجد عتبة بارتفاع ١٠ سم عند المدخل لذلك انت بحاجة الى القليل من المساعدة
Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes
Measurements
not calculated yet
View photos
Are all public spaces have an accessible route of travel?
No
Measurements
not calculated yet
View photos
No photos are attached
Is the accessible route to all public spaces at least 0.9 meters wide?
Yes
Measurements
العرض ١٣٠
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
No
Measurements
الطول ١٣٠
View photos
No photos are attached
2.3.1.Are all aisles and pathways to materials and services at least 0.9 meters wide؟
No
Measurements
العرض ١٢٥
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a full wheelchair turn?
No
Measurements
not calculated yet
View photos
No photos are attached
In circulation paths through public areas are all obstacles cane-detectable (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall?
No
Measurements
not calculated yet
View photos
No photos are attached
2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes
Measurements
not calculated yet
View photos
No photos are attached
If emergency systems are provided, do they have both flashing lights and audible signals?
Yes
Measurements
not calculated yet
View photos
No photos are attached
General text description:
يمكن التنقل ولكن بحذر شديد بسبب توزيع الرفوف ولا يمكن الالتفاف بسبب المسافة الضيقة الى حد ما
Are there signs at inaccessible rest rooms that give directions to accessible ones?
No
Measurements
not calculated yet
View photos
No photos are attached
General text description:
لا يمكن تقييمه لعدم الحاجة الى وجود الحمام في المكتبة
If there is an ATM machine, Does the height and depth follow the following requirements in cm:
Yes
Measurements
not calculated yet
View photos
No photos are attached
4.1.2. Is the ATM machine have a verbal or audible sound system? Do controls have raised and braille lettering?
No
Measurements
not calculated yet
View photos
No photos are attached
General text description:
يتوفر نظام الدفع بواسطة الفيزا ويمكن تحريك الجهاز بسهولة
Customers Comments