Is the width between railings or curbs at least 0.9 meters?
Yes
Measurements
View photos
No photos are attached
Are the railings sturdy and between 0.84 and 1 meters in height?
Yes
Measurements
View photos
No photos are attached
Do all inaccessible entrances have signs indicating the location of the nearest accessible entrance?
No
Measurements
View photos
No photos are attached
Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
No
Measurements
View photos
No photos are attached
General text description:
Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes
Measurements
View photos
No photos are attached
Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes
Measurements
View photos
No photos are attached
Do doors in public spaces have at least 0.8meters clear opening, if the door has double openings does at least one of the openings have at least 0.8meters clear opening?
Yes
Measurements
View photos
No photos are attached
2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes
Measurements
View photos
No photos are attached
Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
Yes
Measurements
View photos
No photos are attached
Are the spaces for wheelchair distributed throughout?
Yes
Measurements
View photos
No photos are attached
Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes
Measurements
View photos
No photos are attached
Are knee spaces at accessible tables at least 0.68 meters high, 0.76 meters wide and 0.48 deep?
Yes
Measurements
View photos
No photos are attached
At each type of cashier counter, is there a portion of the main counter that is no more than 1 meters high?
Yes
Measurements
View photos
No photos are attached
On each level, if there are stairs between the entrance and/ or elevator and essential public areas, is there an accessible alternate route?
Yes
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs treads have a non-slip surface?
Yes
Measurements
View photos
No photos are attached
If there is no elevator, ramp or lift, do the stairs have continued rails on both sides, with extensions beyond the top and bottom stairs?
Yes
Measurements
View photos
No photos are attached
Are there ramps, lifts or elevators to all public levels?
Yes
Measurements
View photos
No photos are attached
Are the call buttons in the hallway no higher than 1 meters?
Yes
Measurements
View photos
No photos are attached
Do controls inside the cab have raised and braille lettering?
Yes
Measurements
View photos
No photos are attached
Is the emergency intercom identified by braille and raised letters?
Customers Comments