Zawaya Space


Overview

JUST-Able Evaluation  

Is an adequate number of accessible parking spaces available?
No


Is the route of travel stable, firm, slip resistant and blind friendly (supported textured tiling)?
Yes


Is the route at least 0.9 m in width?
Yes


Can all objects protruding into the circulation paths be detected by a person with visual disability using a cane? (located within 0.7 meters of the floor, or higher than 2.3 meters, or protruding less than 0.1 meters from the wall)
Yes


Do curbs on the routes have curb cuts at drives, parking and drop-offs?
Yes


If there are stairs at the main entrance is there also a ramp or lift, is there an alternative accessible entrance?
No


Does the entrance door have at least 0.8 meters door opening (for a double door and at least one 0.8 meters leaf?
Yes


Is there at least 0.5 meters of clear wall space on the full side of the door next to the handle?
Yes


Is the threshold edge less than or equal to 1 cm height, and if beveled is not more than 2 cm meters’ in height?
No


If provided are carpeting or mats a maximum 1 cm height?
No


Are edges of carpeting or mats security installed to minimize tripping hazards?
No


Is the door handle not higher than 1 meter, are the glass doors highlighted with a clear color to differentiate them from the building façade?
Yes


Can doors be opened without too much force, are they operable with a closed fist?
Yes


General text description:
"لا يوجد مصفات مخصصة لذوي الاعاقة و لكن توجد مصفات قريبة للمدخل الرئيسي توجد عتبة خارجية و لكن البلاط المستخدم مناسب ، توجد ممرات بعد المدخل الرئيسي تفي بالغرض و لكن غير مهيئة للاشخاص ذوي الاعاقة البصرية توجد عتبة على مدخل المنشأة اعلى من الارتفاع اللازم و غير مزوده بميلان"

Is the accessible entrance providing direct access to the main floor, lobby, or elevator?
Yes


Is the accessible route to all public spaces at least 0.9 meters wide?
Yes


Is there a minimum circle space of 1.5 meters for a person using a wheelchair in all directions for maneuvering?
Yes


2.4.1. Is the room lighting system moderate and close to the outdoor sunlight? ( moderate lighting not very yellow or very white in color)
Yes


If emergency systems are provided, do they have both flashing lights and audible signals?
Yes


Are signs mounted with Centerline 1.53 meters from the floor?
No


are the signs mounted on the wall adjacent to latch side of door or as close as possible to the door handle?
Yes


Are characters raised in size between 1.5 to 5 cm high, with high color contrast ( for room numbers, restrooms, and exits).
No


Is the text of the sign brailed of the same information?
No


Are all controls that are available for use by the public (Including electrical, mechanical, cabinet, game, and self-service controls) located at an accessible height? The maximum height for side reach is 1.37 meters, and for a forward reach is 1.22 meters. The minimum reachable height is 0.38 meters.
Yes


Are they operable with a closed fist?
Yes


Are the aisles between fixed seating’s (other than assembly area seating’s) at least 0.9 meters wide?
No


Are the tops or tables or counters between 0.71 and 0.86 meters’ height?
Yes


Are knee spaces at accessible tables at least 0.68 meters high, 0.76 meters wide and 0.48 deep?
Yes


If there is no elevator, ramp or lift, do the stairs treads have a non-slip surface?
Yes


Are there ramps, lifts or elevators to all public levels?
Yes


Are there both visible and verbal or audible door opening/ closing and floor indicators (one tone up, two tones down)?
No


Are the call buttons in the hallway no higher than 1 meters?
No


Do controls inside the cab have raised and braille lettering?
Yes


Is there a sign on both door jambs at every floor identifying the floor in raised and braille letters?
No


Is the emergency intercom identified by braille and raised letters?
No


General text description:
"أزرار المصعد من الداخل اعلى من المطلوب و لكنها مزودة بلغة بريل توجد عتبة على باب المساحة بارتفاع اعلى من اللازم ارتفاع ازرار الكهرباء اعلى من المطلوب لا يوجد نظام طوارئ و لكن يوجد درج طوارئ "

If rest rooms are available to the public, is at least one rest room (either one for each sex, or unisex) fully accessibility?
No


Is the doorway at least 0.9 meters clear?
No


Are doors equipped with accessible handles (operable with closed fist), 1-meter high?
Yes


Can doors be opened easily (operable with closed fist)?
Yes


Does entry configuration provide adequate maneuvering space for a person using a wheel chair?
No


In the accessible stall are there grab bars behind and on the side wall nearest to the toilet?
No


Is the toilet seat 0.43 to 0.48 meters high?
Yes


Is the toilet seat supported with a built-in bidet or does it have a handheld bidet?
Yes


General text description:
المرحاض غير مؤهل لذوي الاعاقة و يحتاج لتعديلات انشائية

General text description:

Customer Reviews

5

(0 Rating)

Customers Comments

Working Hours

  • Monday 10:00 - 22:00
  • Tuesday 10:00 - 22:00
  • Wednesday 10:00 - 22:00
  • Thursday 10:00 - 12:00
  • Friday 00:00 - 20:00
  • Saturday 10:00 - 22:00
  • Sunday 10:00 - 22:00

JUST-Able

Subscribe to our newsletter and don’t miss any updates